Harver Induction Geysers

AVAILABLE MODELS




CN30L 2kw

CN50L 4kw

CN75L 4kw


INDUCTION GEYSER INFO

  • NRCS-CERTIFIED – SANS/IEC 60335-2-21
  • SANS 151 TESTING IN PROGRESS
  • 3 YEAR WARRANTY ON MANUFACTURE & MATERIAL DEFECTS
  • 1 YEAR WARRANTY ON ELECTRICAL PARTS
  • STAINLESS TANKS
  • ELECTRONIC TEMPERATURE SENSING TECHNOLOGY THAT IS MORE ACCURATE
  • HIGH DENSITY THERMAL INSULATION LAYER, TO SUSTAIN THE WATER TEMPERATURE
  • MULTIPLE PROTECTION MEASURES IN PLACE : DRY BURN, OVERHEAT, LOW /HIGH VOLTAGE, SURGE AND OVER HEAT PROTECTION
  • THERMOSTAT CUT OUT SET AT 93 DEG.
  • SANS 198 APPROVED KWIKOT  T/P VALVE PRE-INSTALED
  • EXPANSION/NON RETURN VALVE SUPPLIED
  • ONLY REQUIRES 15 AMP WALL PLUGS.
  • NOTE: THIS IS NOT AN INSTANT HEATER

TECHNICAL SPECIFICATIONS

Unit

30 Litre

50 Litre

75 Litre

Power supply

220-240V 50/60Hz

220-240V 50/60Hz

220-240V 50/60Hz

Rated Power

2KW / 2KW+2KW

2KW / 2KW+2KW

2KW+2KW

Rated Current

9 /9+9 A

9 /9+9 A

9+9 A

Water pressure

0.6Mpa

0.6Mpa

0.6Mpa

Waterproof Level

IPX4

IPX4

IPX4

Dimension (mm)

830 x 440 x 240

1180 x 440x 240

1390 x 530 x 290

Heat water temperature from 20-75°C  (Ambient temperature 20°C)

Unit

30L   

50L   

75L

2KW

44min   



2KW+2KW

22min

38min

55min

POSSIBLE USAGE OF HARVER INDUCTION GEYSERS

With reference to the attached Technical Specifications the power usage of the standard resistive geyser and the Harver geyser are calculated and tabulated below:


Standard 2kW 50 litre geyser
(resistive)

Harver 2kW 50 litre geyser
(inductive)

Power consumption to heat water from 20°C to 65°C

2.6 kW in 78 minutes
= 2 kW x 78/60 hour
= 2.6 kWh

2.1 kW in 63 minutes
= 2 kW x 63/60 hour
= 2.1 kWh

50% of annual hot water demand

0.5 x 84 000 litre
= 42 000 litre

0.5 x 84 000 litre
= 42 000 litre

Power consumption to heat 50% of annual hot water demand

42000/50 x 2.6 kWh
= 2 184 kWh

42000/50 x 2.1 kWh
=1 764 kWh
25% reduction in power use



Standard 2kW 100 litre geyser
(resistive)

Harver 4kW 75 litre geyser
(inductive)


Power consumption to heat water from 20°C to 65°C

5.2 kW in 156 minutes
= 2 kW x 156/60 hour
= 5.2 kWh

3.3 kW in 50 minutes
= 4 kW x 50/60 hour
= 3.3 kWh

50% of annual hot water demand

0.5 x 84 000 litre
= 42 000 litre

0.5 x 84 000 litre
= 42 000 litre

Power consumption to heat 50% of annual hot water demand

42000/100 x 5.2 kWh
= 2 184 kWh

42000/75 x 3.3 kWh
=1 848 kWh
18% reduction in power use

Storage volume at 60°C (table 5, column 3): Complies, minimum of 25 litre/capita/day x 2 = 50 litre Heater power (table 5, column 4): 4kW, complies being between 2-5kW per unit

4.1.1 b) solar water heating systems compliance Not applicable.
4.1.2 Requirements for water installations in buildings shall be in accordance with SANS 10252-1 and SANS 10254 To be complied with.
4.1.3 All hot water service pipes with internal diameter ≤ 80mm shall be clad with insulation with a minimum R-value of 1,00 To be complied with.
4.1.4 Thermal insulation, if any, shall be installed in accordance with the manufacturer’s instructions To be complied with.

It is evident from above table that the Harver geyser consumes less electricity than a standard geyser but not the required 50%.
It is recommended that if the overall savings for the whole building with the Induction units fitted does not conform to the regulation an Intergrated solar geyser of 50-85 litre capacity be fitted to augment the induction geyser.
We recommend the Solo Intergrated geyser which we can supply.

The figures below are based on a 8 min shower with 9l/min shower heads using a total of 72L or of hot and cold water.

Water temp based on 20 °C inlet temp

A=    Heating time (Min per °C)
B=    
Capacity of geyser
C=    
Kw Rating of geyser
D=    
Litres of hot water needed for 8 min shower at 39°C
E=    
Temperature of water in geyser after 8 min shower or bath
F=    
Time in min to heat water to Starting temp
G=  
 Kwh used to heat water back to starting temp

Standard geysers

ALL CALCULATIONS BASED ON ESCOM FIGURES





Starting Temp

65


Heat time

Geyser

Rating

Hot water

Temp

Time

Kwh

Min per °C

Capacity

Kw

Litres




A

B

C

D

E

F

G

1.4  

 30

1.5   

29.56

21

62.07

1.5517

1.75

50   

2

29.56

38

46.55

1.5517

3.5

100

2

29.56

52

46.55

1.5517

3.5

150

3

29.56

56

31.03

1.5517

3.5

200

4

29.56

58

23.28

1.5517

FIGURES BASED ON 1.5M BATH AT 200mm DEPTH

Standard geysers

ALL CALCULATIONS BASED ON ESCOM FIGURES





Starting Temp

60


Heat time

Geyser

Rating

Hot water

Temp

Time

Kwh

Min per °C

Capacity

Kw

Litres




A

B

C

D

E

F

G

3.5

150

3

40

49

38

1.8842

3.5

200

4

40

52

28

1.8842

Induction geyser





Starting Temp

75


Heat time

Geyser

Rating

Hot water

Temp

Time

Kwh

Min per °C

Capacity

Kw

Litres




A

B

C

D

E

F

G

0.4







0.7

50

4

29

43

23

1.5073

1.1

75

4

29

53

24

1.5791

LINKING A SOLO INTERGRATED SOLAR GEYSER TO A 75L UNIT

BASIC LAYOUT OF INDUCTION GEYSERS


MANUFACTUERS INSTALLATION DIAGRAM  

1)    THIS UNIT MUST BE INSTALLED AS PER THE DIAGRAM.
2)    THIS A WALL MOUNTED UNIT
3)    NOTE: IT CANNOT BE POSITIONED UPRIGHT OR LAID DOWN ON A SHELF OR THE FLOOR.
4)    ENSURE THE T\P VALVE IS PLUMBED TO THE DRAIN OR ATOMSHPERE IN A SAFE AREA
5)    A THERMOSTATIC TEMPERING VALVE MUST BE USED IF THE TEMPERATURE IS SET ABOVE 60 DEG. (RECOMMENDED)
6)    A 400 KPA PRV VALVE IS RECOMMENDED
7)    THE EXPANSION VALVE WILL OPEN AT 700 KPA
8)    ENSURE THE ELECTRICAL SUPPLY IS CAPABLE OF 22 AMPS WITH 4 KW UNITS ( Min 2.5m² cable)
9)    DO NOT REMOVE 15 AMP PLUG – WARRANTY IS AFFECTED
10)    DRIP TRAY RECOMMENDED IF INSTALLED IN ROOF OR CUPBOARD


SANS 10254 INSTALLATION DIAGRAM

1)    THIS UNIT MUST BE ISTALLED AS PER THE DIAGRAM
2)     THIS IS A WALL MOUNTED UNIT
3)    NOTE: IT CANNOT BE POSITIONED UPRIGHT OR LAID DOWN ON A SHELF OR THE FLOOR
4)    ENSURE THE T\P VALVE IS PLUMBED TO THE DRAIN OR ATOMSHPERE IN A SAFE AREA
5)    A THERMOSTATIC TEMPERING VALVE MUST BE USED IF THE TEMPERATURE IS SET ABOVE 60 DEG. (RECOMMENDED)
6)    THE MULTI VALVE MUST BE AN APPROVED MAKE AND A 400 KPA VALVE IS RECOMMENDED
7)    ENSURE THE ELECTRICAL SUPPLY IS CAPABLE OF 22 AMPS WITH 4 KW UNITS (Min 2.5m² cable)
8)    DO NOT REMOVE 15 AMP PLUG – WARRANTY IS AFFECTED
9)    DRIP TRAY RECOMMENDED IF INSTALLED IN ROOF OR CUPBOARD


WARRANTY CONDITIONS

Thank you for purchasing our product. We certify that the split magnetic water heater has successfully passed the quality check.
The warranty covers manufacture and material defects provided:
The unit has been installed correctly and the unit is under normal use Warranty is null and void if the plug top is removed from the power cord
The unit is serviced by an authorised person.
The company will not be held responsible for any injury to persons, loss or damage to property due to product failure, malfunction operation etc, resulting from using the unit other than in accordance with the instructions provided.
The warranty is for 3 years on tank and 1 year on Electrical parts.